Xem ảnh lớn

WS-X45-Sup7L-E

Modules & Cards

0

WS-X45-SUP7L-E Overview WS-X45-SUP7L-E, the Cisco Catalyst 4500E supervisor engine 7L-E, is the leading borderless networks access and aggregation supervisor engine for the Cisco Catalyst 4500E series. Best-In-Class resiliency feature improves the network reliability and allows supervisor-engine redundancy to prevent network outage when integrates with Cisco catalyst 4507R-E, 4507R+E, 4510R+E or 4510R-E chassis. Notice that WS-X45-SUP7L-E= is similar with WS-X45-SUP7L-E, except that WS-X45-SUP7L-E= is a spare one.  Quick Spec Figure 1. WS-X45-SUP7L-E Appearance. Table 1. Product Code WS-X45-SUP7L-E Centralized switching capacity 520 Gbps Per-slot switching capacity 48 Gbps Throughput 225 Mpps for IPv4 110 Mpps for IPv6 225 Mpps for L2

WS-X45-SUP7L-E Overview

WS-X45-SUP7L-E, the Cisco Catalyst 4500E supervisor engine 7L-E, is the leading borderless networks access and aggregation supervisor engine for the Cisco Catalyst 4500E series. Best-In-Class resiliency feature improves the network reliability and allows supervisor-engine redundancy to prevent network outage when integrates with Cisco catalyst 4507R-E, 4507R+E, 4510R+E or 4510R-E chassis.

Notice that WS-X45-SUP7L-E= is similar with WS-X45-SUP7L-E, except that WS-X45-SUP7L-E= is a spare one. 

Quick Spec

Figure 1. WS-X45-SUP7L-E Appearance.

WS-X45-SUP7L-E

Table 1.

Product Code

WS-X45-SUP7L-E

Centralized switching capacity

520 Gbps

Per-slot switching capacity

48 Gbps

Throughput

225 Mpps for IPv4

110 Mpps for IPv6

225 Mpps for L2 Bridging

IPv4 routing entries

64,000

IPv6 routing entries

32,000

Multicast routes

32,000

CPU

Dual core; 1.5 GHz

CPU queues

64

Synchronous Dynamic RAM (SDRAM)

2 GB

Boot flash

1G

Security and QoS hardware entries

64,000

Dynamic Host Configuration Protocol (DHCP) snooping entries

12,000

Cisco Network Admission Control (NAC)

4,000

MAC addresses

55,000

Active VLANs

4,094

Address Resolution Protocol (ARP) entries

47,000

Spanning Tree Protocol instances

12,000

Switched virtual interfaces (SVIs)

4,094

SPAN

8 bidirectional sessions (ingress and egress)

Product Details

Figure 2. WS-X45-SUP7L-E can be installed in the Catalyst 4500 switch Chassis.

WS-X45-SUP7L-E installed in the switch

Figure 3. WS-X45-SUP7L-E Front Panel.

WS-X45-SUP7L-E Front

Note:

① STATUS LED   ② Reset Button   ③ ACTIVE SUP LED   ④ UTILIZATION LED   ⑤ USB Ports   ⑥ Secure Digital Port   ⑦ Console Port

⑧ 10/100/1000 MGT Port   ⑨ 4 × 1G/10G Uplinks SFP/SFP+

Supported Line Cards and Modules

Table 2. Recommended Cisco Catalyst 4500E Series Line Cards and Modules.

Model

Description

WS-X4748-UPOE+E

Cisco Catalyst 4500E Series, 48-port 802.3af PoE, 802.3at PoEP, and UPoE 10/100/1000

WS-X4748-RJ45V+E

Cisco Catalyst 4500E Series, 48-port PoE 802.3at 10/100/1000 (RJ-45)

WS-X4712-SFP+E

Cisco Catalyst 4500E Series, 12-port 10 Gigabit Ethernet (SFP+)

WS-X4648-RJ45V+E

Cisco Catalyst 4500E Series, 48-port Premium PoE 10/100/1000 (RJ-45)

WS-X4648-RJ45-E

Cisco Catalyst 4500E Series, 48-port 10/100/1000 (RJ-45)

WS-X4606-X2-E

Cisco Catalyst 4500E Series, 6-port 10 Gigabit Ethernet (X2)

WS-X4624-SFP-E

Cisco Catalyst 4500E Series, 24-port Gigabit Ethernet (SFP)

WS-X4612-SFP-E

Cisco Catalyst 4500E Series 12-port Gigabit Ethernet (SFP)


WS-X45-SUP7L-E Specification

WS-X45-SUP7L-E Specification

Feature

Chassis compatibility

The Supervisor Engine 7L-E is supported on the Catalyst 4503-E, Catalyst 4506-E, Catalyst 4507R-E, and the Catalyst 4507R+E switch chassis. The Supervisor Engine 7L-E is not supported on the Catalyst 4510R-E or the Catalyst 4510R+E switch chassis.

Software requirements (minimum)

Refer to your software release notes for the latest software release requirements.

Chassis slot restrictions

•Catalyst 4503-E: Slot 1 only

•Catalyst 4506-E: Slot 1 only

•Catalyst 4507R-E and Catalyst 4507R+E: Slot 3 and slot 4

Bandwidth per slot

48-Gbps

Supervisor Engine 7L-E Front Panel Features

STATUS LED

The STATUS LED indicates the current health of the supervisor engine and the current software state.

•Green—All diagnostic tests have passed.

•Orange—System boot or a diagnostic test is in progress.

•Red—A diagnostic test failed.

•Off—The supervisor engine is disabled or is not powered up.

RESET switch

The RESET switch is used to reset and restart the switch.

Note Use a paper clip or other small, pointed object to press the RESET switch.

ACTIVE SUP LED

The ACTIVE SUP LED indicates whether the supervisor engine is active or in standby mode in redundant supervisor engine configurations.

•Green—Supervisor engine is active (in redundant supervisor engine configurations).

•Off—Supervisor engine is in standby mode (in redundant supervisor engine configurations).

UTILIZATION LEDs

When the switch is operational, the eight UTILIZATION LEDs indicate the current traffic load over the backplane as an approximate percentage value. Each LED represents approximately 12.5 percent of load.

USB connectors

Two USB 2.0 ports are provided:

•Port 1 is not supported at this time.

•Port 2 operates in host mode (downstream). It has a USB type A connector and a standard USB 2.0 device such as a flash memory device, can plug into this connector.

SECURE DIGITAL slot

A standard Secure Data (SD) memory card interface is provided on the front panel.

CONSOLE port

A 10/100/1000 port that uses an RJ-45 connector. The console port allows you to access the switch either locally (with a console terminal) or through a modem (remote). The port has an RJ-45 connector. The console port allows you to perform the following functions:

•Configure the switch from the CLI.

•Monitor network statistics and errors.

•Configure SNMP agent parameters.

10/100/1000 MGT port

The Ethernet management port is a Layer 3 host port to which you can connect a PC. You can use the Ethernet management port instead of the switch console port for network management. When managing a switch, connect the PC to the Ethernet management port on a Catalyst 4500 E-series switch.

•Green—The link is operational.

•Orange—The link is disabled by user.

•Flashing orange—The power-on self-test indicates a faulty port.

•Off—No signal is detected or there is a link configuration failure.

Note When connecting a PC to the Ethernet management port, you must assign an IP address.

LINK LED

The 10/100/1000 MGT port has a LINK LED associated with it.

UPLINK (SFP/SFP+) ports

The Supervisor Engine 7L-E has four uplink ports. Ports 1 and 2 support either 10GBASE SFP+ transceivers or 1000BASE SFP transceivers. Ports 3 and 4 support only 1000BASE SFP transceivers. There are restrictions on the use of the uplink ports in both single supervisor engine and redundant supervisor engine configurations and both 10-G and 1-G operation.

Uplink port LEDs

There are two types of LEDs associated with the supervisor engine uplink ports.

Uplink port ACTIVE LEDs

Uplink ports on the supervisor engine are active in pairs. Two LEDs on the front panel show this activity. One LED, labeled 1G/10G 1-2 ACTIVE, indicates ports 1 and 2 are active; the other is labeled 1G 3-4 ACTIVE and indicates ports 3 and 4 are active.

In standalone supervisor engine configurations operating in 1-Gigabit mode, all four uplink ports are active; both the 1-2 ACTIVE LED and 3-4 ACTIVE LED are lit green.

In redundant supervisor engine configurations, only the 1-2 ACTIVE LED is lit green. When one supervisor engine is removed, both the 1-2 ACTIVE LED and 3-4 ACTIVE LED are lit green on the remaining supervisor engine when it is in 1-Gigabit operation. In 10-Gigabit mode, only the 1-2 ACTIVE LED is lit.

Uplink port STATUS LEDs

Uplink ports 1 and 2 each have two uplink port STATUS LEDs. The 1G LED displays port status when a 1-GB SFP transceiver is installed in the port socket. The 10G LED displays port status when a 10-GB SFP+ transceiver is installed in the port socket. Port 3 and Port 4 support only 1-GB SFP transceivers and have only the 1G port status LED.

•Green—The link is operational.

•Orange—The link is disabled by user.

•Flashing orange—The power-on self-test indicates a faulty port.

•Off—No signal is detected or there is a link configuration failure.

Sản phẩm liên quan